Infusion Pump, Medcaptain brand, model SYS-6010, 1 year warranty.

Intravenous solution control device (Infusion Pump), brand Medcaptain, model SYS-6010, quality brand product. It has high resolution and accuracy, safe to use. Free shipping nationwide

Intravenous solution control device (Infusion Pump), brand Medcaptain, model SYS-6010
“Quality brand products High resolution and accuracy can be used safely”

Purpose of use

Infusion Pump is used to control the administration of solutions such as nutrients and medicines intravenously (vein) which requires precision and precision in volume, number of drops, time and constant solution flow rate. or as the doctor has correctly configured

1. Product details

It is a solution control device that can use standard IV sets of 20 or 15 d/ml from MedCaptain, ME Meditek, Terumo, B. Braun and IV Sets for drug administration from Kawasumi, Fresenius Kabi, Baxter when received. Calibrate first
It is a solution control device that has the ability to detect air bubbles as small as 0.025 mI or more and can be adjusted to 7 levels.
The blockage warning within the IV Set line can be set to 11 levels.
It is a solution control device that uses AC 100-240V, 50/60 Hz, consumes 25 VA and can use DC 12V direct current.
It is a solution control device with a 11. 1V, 1500 mAh lithium battery that can provide solution. continuously for not less than 5 hours (when using a flow rate of 25 ml/hr.)
It is a solution control device with dimensions of 100
Uses a 11.1 V 1500 mAh lithium battery.
It is a solution control device that meets safety standards EC60801-1, EC50601-2-24,
IEC60601-1-8 and IEC60601-1-2
Classification Tool Class 1, Type CF, IPX2
Can adjust the form of intravenous solution delivery to patients in 8 formats.
Rate mode: Flow rate and volume setting format.
Time mode: The format for determining the time required for the solution to be completely empty and the volume.
Booy Weight mode, intravenous dosage form By entering details of the dose of medicine and
the patient’s weight, the machine will automatically calculate the flow rate.
Trapezia mode: Intravenous dosage form By entering the details of the medicine, you can
schedule the increase time and decrease the flow rate of the medicine in advance. And the machine will automatically adjust the flow rate.
Loading Dose Intravenous dosage form By entering details of the drug, volume, flow rate
, flow time, loading dose range, the machine will automatically calculate the drug dose as flow rate.
Sequence mode, form of intravenous drug administration by entering medication details Set flow rate
and time for up to 10 intervals.
Drip mode, a form of intravenous solution delivery By specifying the number of drops per milliliter and
the desired volume. (Must be used in conjunction with the Drop sensor, which is an accessory)
Micro Mode: A form of intravenous solution or medicine given in small amounts to children or infants.

2. Feature details

Adjusting the maximum solution flow rate of the machine
1. Maximum flow rate 1 – 1,200.0 ml/hour in the case of using IV set 20 d/ml.
Adjusting the maximum volume flow rate of the machine
1. Volume 0.1- 99.99 ml., resolution can be adjusted 0.01 ml.
2. Volume 100 – 999.9 ml., resolution can be adjusted 1 ml.
3. Volume 1,000- 9,999g has milliliters. Can adjust the resolution to 1 milliliter at a time.
Adjusting the maximum volume rate that the machine can display from 0.01 – 99,999.99 ml.
The accuracy in giving the solution is not more than 5% after calibrating the IV Set with the machine.
The maximum flow rate of Purge mode can be adjusted to a maximum of 1.200.0 ml/h.
Can adjust the flow rate. Bolus mode can be set 0.1- 1200.0 ml/h.
Can be set to use the Auto bolus system, where the machine will calculate the flow rate from the total bolus volume, but the bolus flow rate will not be lower than the normal flow rate given to the patient.

Flow rate KVO mode can adjust the flow rate from 0 1-5.0 ml/h.

There is an audible warning system and a message display when at least the following abnormalities occur:
1. When the solution controller is nearly empty (Near end)
2. When the solution controller gives out the complete amount of solution ( Infusion end)
3. When the infusion controller is blocked (Occlusion)
4. When the infusion controller has a low battery level (Low battery)
5. When the infusion controller battery runs out (Battery Empty)
6. When The solution control unit is not plugged in to charge (No power supply).
7. When the solution control unit has a system that does not work normally (System trouble).
8. When the solution control unit finds air bubbles in the set during operation ( Air bubble)
9. Reminder when the power is left on (Reminder Alarm)

There is an audio system to alert the machine when no corrections have been made.

Repeat Alarm when pressing to mute the Alarm has not yet been fixed. The alarm will sound again after 2 minutes of turning off the Alarm sound.

There is an Event recording system that can record details of past 2000 events of machine usage.

There is an Alarm volume setting system that can adjust the alarm sound to 11 levels.

There is a Power supply switching system. When unplugged, the machine will automatically switch to battery power.

3. Wifi system connection

The machine can send data on drug or solution administration to the Nurse station through the Central Monitoring system to monitor drug or solution administration. and can send warning signals when abnormalities occur in real time (additional equipment)

There is a Voice communication system. You can talk with the audio system between the unit in the patient room and the nurse station through an additional device. (additional equipment)

4. Equipment for use

Carrying handle and saline pole holder, 1 set
1 set of wires
1 set of salt water poles
Thai/English work manual, 1 set

5. Product warranty
Product guaranteed for 1 full year.

There is a service repair center. with a team of technicians providing service Ready to give advice How to use 24-hour service